1
|
6
|
Water quality: water clear enough to clearly see bottom of pool and pool drain |
No |
No
|
No |
Some leaves and debris covering main drain at time of inspection. .2535(2) Main drains must be clearly visible from the pool deck. Operator cleared drains. Corrected. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Leaves and debris in skimmer baskets at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned baskets. Corrected.
Weir missing at time of inspection. 2518(k) Replace missing weirs. Operator replaced missing weir. Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
One gate zip tied closed at time of inspection, not working properly. Gate on back right not self-latching at time of inspection.
.2537(b) All gates and doors shall be self-closing, self-latching.
**30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when corrected to lift ITS. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed cracked/chipped coping at sunshelf, gap in tiles at "0 FT" depth marker at sunshelf, greater than 1/2". "NO STEP" tile not attached to deck at time of inspection. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
**30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when corrected to lift ITS. | |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Obseved bag of dry chemicals on floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Operator moved off floor. Corrected. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower off/inoperable and winterized at time of inspection. .2626(h) Shower(s) shall be provided. |