5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed records indicating cyanuirc acid (CYA) at 160. CYA over 100ppm.
.2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed ring buoy rope over 33'. Corrected during inspection.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed door to clubhouse self closing, not self latching.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
Observed gate not self closing.
.2537(b) All gates shall be self-closing, self-latching. |