Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRESIDENCES AT WEST MINT
Address9610 STONEY GLEN DR
 
City/State/ZIP
CHARLOTTE NC 28227
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/18/2023
Final Score @ Grade
30
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Pool pH measured 7.0. Pool pH shall be 7.2 to 7.8. CDI - Operator corrected pH to 7.6 by end of inspection.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Clean debris out of pool.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Clean debris out of skimmers.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. All 3 ladders are very loose and missing rungs.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope attached to ring buoy was 55 feet. CDI - Operator cut rope to 50 feet.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Flow meter was not operating. Repair/replace flow meter.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Bags of chemicals observed on floor in pump room. Store off the floor.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Pipe from sand filter and top of backwash pit needs an air gap. Cut pipe so there is space between outlet of pipe and rim of backwash pit.