|
13
|
0
|
Food in good condition, safe & unadulterated |
Yes |
No
|
No |
3-202.15 Food packaging must be in good condition, intact and protect the food inside. Pf Observed dented can of mushrooms in WIC. CDI-PIC voluntarily discarded can of mushrooms. |
|
22
|
1.50
|
Proper cold holding temperatures |
Yes |
Yes
|
No |
REPEAT
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P Observed four containers of coleslaw above 41F in WIC tightly sealed. CDI - PIC stated items were prepared roughly 2hours ago and removed the lids from containers to allow for rapid cooling. See temp chart. No points escalated at this time due improvement in cold holding TCS foods.
For more information, please visit: www.mecknc.gov/foodsafety or view our training videos at the following weblinks: What are TCS Foods https://www.youtube.com/watch?v=q0iLZb7v0UM and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
Yes |
Yes
|
No |
REPEAT
4-101.19/4-202.16 Non FOOD-CONTACT SURFACES of EQUIPMENT that are exposed to splash, spillage, or other FOOD soiling or that require frequent
cleaning shall be constructed of a CORROSION-RESISTANT, nonabsorbent, and SMOOTH material. NonFOOD-CONTACT SURFACES shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Observed rust wired storage shelves inside WIC. Repair or replace.
4-501.11 Maintain equipment in good repair. Observed two in-use metal mesh breading baskets with white paint peeling showing exposed bare metal. CDI - PIC voluntarily discarded both items. |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
Repeat
6-201.13 Provide a wall to floor joint that is sealed and coved when flood cleaning methods are used. Floor must be graded to drain to functioning floor drains. Observed improvement with floor to wall joint on wall where hand washing sink and dish machine are located. PIC will continue to install more floor to wall joints.
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed absorbent ceiling tile near flip top unit. PIC has ordered replacements.
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed black build up on walls near prep sink and hot holding boxes. Increase frequency of cleaning. |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-303.11 Provide required lighting intensity. Observed only 3foot candles in WIF. CDI - PIC will have light bulb replaced. |