| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
4
|
1
|
Proper eating, tasting, drinking, or tobacco use |
Yes |
No
|
No |
2-401.11 Cover and store employee drinks to prevent contamination of food or utensils.
observed uncovered beverages in the kitchen. CDI by covering beverages. |
|
13
|
1.50
|
Food separated and protected |
Yes |
No
|
No |
3-302.11(A)(4) Protect food in storage using covered containers, intact wrappings, or packaging.
observed some uncovered continers of food in walk-in cooler. CDI by adding lids to food. improvement noted from previous inspection. |
|
14
|
1.50
|
Food-contact surfaces: cleaned and sanitized |
Yes |
No
|
No |
4-602.11 Clean the equipment and utensils used with TCS foods as required to avoid contamination. -P
observed raw shrimp being prepared on prep cooler cutting board area. Area was not properly washed, rinsed, and sanitized.
Cloth used from sani bucket containing 0ppm chlorine. |
|
36
|
1
|
Insects and rodents not present; no unauthorized animals |
No |
No
|
No |
6-501.111 Keep the premises free of insects, rodents, and other pests.
observed cockroaches in kitchen. establishment will continue to use approved pest control methods. |
|
41
|
0
|
In-use utensils: properly stored |
No |
No
|
No |
3-304.12 Store in-use utensils in a clean, dry place, in food with handles out, in 135F or greater water or in running water which quickly moves food particles to the drain.
observed ice scoop handle stored in ice. |
|
42
|
1
|
Utensils, equipment and linens: properly stored, dried and handled |
No |
Yes
|
No |
4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing.
observed several wet tight stacked containers on the drying rack. |
|
53
|
0
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair.
observed displaced/damaged ceiling tiles next to hood system.
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure.
observed cob webs on ceiling in warewashing room. |
|