| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
8
|
0
|
Hands clean & properly washed |
Yes |
No
|
No |
2-301.14 (E) Wash hands after handling soiled equipment or utensils. -P- Observed food employee handle dirty dishes and then begin to handle clean dishes without washing hands.-CDI- EHS educated food employee on when to wash and food employee washed hands. -0- |
|
15
|
0
|
Food separated & protected |
Yes |
No
|
No |
3-304.15(A) Discard gloves after a task is complete or any time they are damaged or soiled. -P- Observed food employee handle dirty dishes and then handle clean dishes without changing gloves. -CDI- EHS educated food employee on when to change gloves and food employee changed gloves. -0- |
|
16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
Yes |
No
|
No |
4-602.11 (A) (4) Food contact surface of a thermometer shall be cleaned, and sanitized per 4-702.11/4-703.11, before using or storing. -P.- Observed thermometer stored clean with visible food debris. -CDI- EHS educated PIC on cleaning thermometer before and after use and thermometer was cleaned. -1.5- |
|
43
|
0
|
In-use utensils: properly stored |
Yes |
No
|
No |
3-304.12 (B) In-use utensils for food that is not TCS must be stored with their handles above the top of the food within containers or equipment that can be closed. Observed scoop stored inside of flour with no handle. -CDI- PIC removed. |
|
44
|
0
|
Utensils, equipment & linens: properly stored, dried & handled |
No |
No
|
No |
4-903.11(B)(2) Clean equipment and utensils shall be stored covered or inverted. Observed clean plates stored in dry dish storage upright with no covering. -0-
4-903.11(B)(1) Clean equipment and utensils shall be stored in a self-draining position that allows for air drying. Observed standing water in ladles stored as clean. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed gasket out of moulding in door in bottom part of prep unit. -0- |
|
48
|
0
|
Warewashing facilities: installed, maintained & used; test strips |
Yes |
No
|
No |
4-301.12(A) Provide a three compartment sink for manually washing, rinsing and sanitizing of equipment and utensils. -Pf- Observed only one dish stopper for 3-comp sink. -CDI- PIC went to buy additional dish stoppers. -0- |
|
49
|
0.50
|
Non-food contact surfaces clean |
No |
Yes
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed top of dish machine in need of cleaning. Increased and more thorough cleaning frequency recommended. **REPEAT** -0.5- **POINTS NOT ESCALATED DUE TO IMPROVEMENT** |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. Observed leak at spray sink faucet near and prep sink faucet to right of spray sink. Repair. -0- |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed small hole in ceiling tile near 3-comp sink. -0- |
|
56
|
0.50
|
Meets ventilation & lighting requirements; designated areas used |
No |
Yes
|
No |
6-305.11/6-501.110 Designate and use an area for the orderly storage of employees' clothing and possessions. Observed employee phone stored on prep table. Observed employee food stored over retail items in lowboy cooler and on top of prep tables. **REPEAT** -0.5- |