| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No total alkalinity or cyanuric acid checks this month. No recent pool maintenance activities. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. - Intent to suspend item.
Cyanuric acid at 100 - 110 ppm for the last 2 months. .2535(4) The cyanuric acid level shall not exceed 100 ppm. - Intent to suspend item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Leaves on pool floor and partially covering main drains. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir installed upside down, two weirs missing. Was noted on previous inspection. .2518(k) Provide functional weirs. - Intent to suspend item.
Most skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Depth markers on pool deck and pool wall at sunshelf in inches. .2523(c) Depth markers shall include the word "feet" or symbol "ft". - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder installed < 3” from pool wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall to ladder rung.
Ladder loose and missing endcap. .2521 Install ladders per manufacturer instructions.
Some handrails loose. .2521 Install handrails per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Body hook not attached to pole. Body hook screws not observed. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Corrected.
Body hook on the ground behind bushes. This is a recurring issue. .2530(a) Lifesaving equipment should be conspicuously and conveniently located. - Will follow up with facility to correct. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Children should not use the swimming pool portion of sign black, no longer legible. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Intent to suspend item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Address and phone number heavily faded. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Most piping not labeled. .2518(d) Piping and valves shall be labeled with color codes with a legend or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash lines extend into backwash pit. .2513(b) Filter backwash shall be discharged through an air gap. |