Water quality: pool water pH |
No |
No
|
No |
pH 7.1 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8. Operator corrected to 7.5. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing maintenance and some cyanuric acid checks read "CYA" rather than number.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Tiling on wall starting to break out. Keep pool walls in good repair.
*Must correct by 2023 permitting season. Lack of severity does not warrant permit action at this time. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
0 ft. on deck depth markers at sun shelf faded. Repair so that 0 ft. is clearly visible.
*Permit item |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Body hook under other maintenance items. Keep accessible. Operator moved and corrected.
.2530(a) Lifesaving equipment should be conveniently located. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Vacuum cap missing on line. Line off. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010.
*Permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Ventilation not working in pump or chemical room at time of inspection. Observed chemicals of buckets stored on floor in pump room. Some items within 3' of piping in pump room..2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |