NameFOUNTAINS SOUTHEND APARTMENTS
Address126 NEW BERN ST
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/24/2020
Final Score @ Grade
14
General CommentsLifted suspension for drain covers. Changed to "A" Open for Business. Approved PDSC, main drains 4 Hayward WG1032 BHF, installed 10/28/20. Inspection with Edwin Marquez and LeAndrea Combo Report to Edwin Marquez No signature due to COVID-19

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some small pieces of tiling on wall missing by depth markers on shallow and deep end. Keep in good repair. No offsets greater than 1/2". Lack of severity does not warrant permit action.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Depth marker "0 FT" placed over "IN" tile at 4 IN depth of pool, reading 4 0 FT. .2523(a) Provide depth markers on pool walls and pool deck at both ends of the pool. Pool depth is 0 FT 4 IN at this point. Operator added "IN" by 4, to read 4 IN, 0 FT. Markers are correct spacing apart. Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No One inlet fitting not screwing completely into wall, but in tact, not protruding greater than 2". .2518(i) Provide inlet fittings in good repair. Operator removed and is ordering new replacement. Send verification to Marie Daley at 704-507-6806.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Ventilation not working in pump or chemical room at time of inspection. Observed chlorine puck buckets stored on floor in pump room. Some items within 3' of piping in pump room..2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.