Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameQUEENS UNIVERSITY - LEVINE CTR
Address2201 WELLESLEY AVE
 
City/State/ZIP
CHARLOTTE NC 28207
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/7/2019
Final Score @ Grade
16
General CommentsIntent to Suspend issued for chemical storage.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Wall depth marker covered by timer at 9 ft 10 in. Per operator, in use for NCAA tournment, and will not be in use after preparation for race. .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Some diving platforms at 32" above water line. In water greater than 5 ft., platforms shall not exceed 30" above the water line. .2517 Diving equipment shall be installed in accordance with Rule .2517.
22 6 Premises: emergency telephone provided No No No No dial tone at emergency phone at initial pick-up. Corrected during inspection. .2530(f) Emergency phone shall remain operable.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemical enzymes and other chemicals stored in pump room. Pool built post-2004 and was approved with chemical storage room. Move chemicals to chemical storage room. Intent to Suspend issued. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Multiple sinks in varsity locker room and visitor men's and women's locker rooms with soap not operational or out of soap. Men's varsity locker room not viewed at time of inspection due to occupancy. .2626(j) Provide soap and soap dispenser, no glass, at each sink. Floor drain in middle shower of women's varsity locker room with standing water. Repair drain to drain freely. Some staining and build-up on locker room floors. Some water damage on ceiling in the men's visitor locker room. .2626(m) Keep restrooms and fixtures clean and in good repair.