Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRITZ-CARLTON CHARLOTTE, THE
Address201 E TRADE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 10/10/2016
Final Score @ Grade
32
General CommentsImmediate Suspension issued for pH and VGB - drains secure to wall and suction hazard. Note: 2015 permit posted. Post 2016 pool permit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Spa pH at 6.8. Maintain at 7.2 to 7.8. Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Alkalnity not recorded weekly. Record weekly.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No One main drain on spa wall not attached to wall. Some drains without stainless steel screws. Secure to wall and replace screws with stainless steel. Immediate Suspension issued. PDSC forms indicate that drains for jets are tied together. 3 main drains present - can only handle 246 gpm. Max flow for WFK-8, 2hp pumps is 280 gpm. Immediate Suspension issued for suction hazard. Drains cannot handle flow from pumps.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Some mildew on walls of skimmer under lid. Keep clean.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Handrail loose at steps. Keep in good repair.
18 4 Premises: lifeguards present or warning signs posted No No No Warning sign states "doctors". Shall state "doctor."
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Keep operational.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One sink in men's restroom not operable. Repair sink.