NameDRURY INN AND SUITES
Address6920 NORTHLAKE MALL DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 12/15/2025
Final Score @ Grade
30
General CommentsCPO Rodney Searcy not present for today’s inspection. Went over inspection with manager Katherine Conrad. 5 gallon buckets of liquid chemicals in the pump room not labeled appropriately. Ensure chemicals are stored in containers that are designed for that product and reflect the product stored inside. Observed spa with heavy foam when the jets are running. Defoamer added to help. Emergency phone number posted goes to a reservation call center. Recommend rerouting so calls go to front desk. 2HP motor in spa jet pump moved to unlabeled Pentair Challenger filtration pump. Our records show that this is a 1 HP pump, but without the label, will need to provide pictures of the impeller serial number to verify that this is a 1 HP pump. Bonding wire not attached to filtration or jet pump motors. G.S. 130A-(2)3 Bonding wire shall be attached to the pump motor by a licensed electrician. New 2HP motor installed on jet pump. Jet pump motor moved to filtration pump, back of filtration motor removed, wires exposed. Will need work completed by a licensed electrician and an electrical permit and passing inspection from Mecklenburg County Code Enforcement prior to 2026 pool permit being issued. Immediate suspension issued 3) 6) G.S. 130-A(2)3

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Spa pH < 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No New 2HP motor installed on unlabeled pump. Need to verify that it is indeed a 1 HP pump with impeller documentation or install 1 HP motor on pump. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Immediate suspension item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer basket broken. .2518(k) Replace missing or damaged skimmer basket. - Intent to suspend item. Skimmer turned off in the pump room. .2518(k) The flow through rate for any one skimmer shall be between 20 GPM and the max flow certified under NSF 50. - Intent to suspend item.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Intent to suspend item.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Underwater light partially popped out of the light niche. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. - Intent to suspend item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Acid feeder fed continuously during inspection. Control board reading 8.0, pH < 6.8. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some items stored directly beside or on top of equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemical storage room very cluttered. Lots of chemicals stored on top of each other. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.