Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDRURY INN AND SUITES
Address6920 NORTHLAKE MALL DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 11/15/2017
Final Score @ Grade
20
General CommentsPosted permits are from last year. Post current permits in the pool area. Permits can be found at Meckpools.Charmeck.org. *Imminent Hazard - spa motor not bonded to the spa. Ensure that spa motor is properly bonded to the spa and is inspected by Code Enforcement. Immediate suspension issued. 3) 24) Contact Will Harrison (704-507-6824) for reinspection when issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH < 6.8. Maintain between 7.2 and 7.8. - Immediate suspension item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Plaster chipping and pitted. Maintain in good condition.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Weir missing. Install functional weir. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter missing. Install flow meter that is capable of measuring 1 1/2 times the flow of the spa and is accurate to within 10 percent of true flow. - Intent to suspend item. Spa filtration motor not bonded to the spa. Ensure that motor is properly bonded to the spa and is inspected by Code Enforcement. - Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some leaks in the pump room. Fix leaks. Chemicals stored in the pump room. Store chemicals in the chemical storage room. Exhaust fans for pump room and chemical storage room not working. Provide either continuous forced air ventilation or cross ventilation.