NameHILTON GARDEN INN AYRSLEY
Address1920 AYRSLEY TOWN BLVD
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 2/23/2026
Final Score @ Grade
20
General CommentsIssued Intent to Suspend (ITS) for fitting missing and records. Correct and contact Marie Daley at 704-507-6806 to lift ITS “W” ITS status Inspection with Ron Pauling Permit Restrictions: 1) Filtration - Flow meter must remain operable with flow from 49 gpm to 55 gpm to meet turnover and flow restriction of the skimmer. Flow greater than 100 gpm exceeds the main drains. Suction Hazard. 2) Feature - Flow meter shall remain operable with flow no greater than 100 gpm due to flow restriction of the drain cover. Suction Hazard. Looking into pipe used for plumbing

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Observed pH at 7.0. .2335 Maintain pH between 7.2- 7.8. Operator corrected to 7.2.
4 6 Water quality: water temperature of heated pool No No No Spa temperature 104.5 F at time of inspection. .2535(12) Heated spa temperature greater than 104 F. Maintain spa temperature at 104 F or below. Operator turned heat down and corrected to 102.5 F.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records have out of range pH for multiple days with no maintenance correction or closure. Missing weekly alkalinty. Temperature not accurate on records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked alkalinty and corrected. *permit item
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Inlet fitting missing and hole in wall (unsure of correct fitting) needs to be corrected with correct fitting (after identifying) .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. *Permit item