Inspection Date 1/7/2021
Final Score @ Grade
24
General CommentsITEMS THAT MAY WARRANT AN INTENT TO SUSPEND PERMIT: - Weirs must be present at all skimmers **Please ensure spa records are accurately kept, with pH, bromine, temperature, and main drain daily. Total akylinity checked weekly. Stacie Rhea present at time of inspection. Please contact EHS when ready to have suspension lifted, (704)-371-1589.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(5) Maintain bromine at least 2.0 ppm. Observed bromine level at 0ppm at time of inspection. CDI: CPO corrected bromine levels. Spa now reads 2.0ppm.
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH of 8.0 at time of inspection. CDI: CPO corrected pH levels. Spa now reads 7.4.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed walls at water line stained with gray film.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed missing weir. MAY WARRANT INTENT TO SUSPEND.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed standing water in pump room floor.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(i) Water in restrooms shall not exceed 110 F. Observed hot water in men's restroom at 129F and women's restroom 114F.