Premises Information

Return to Inspections
NameSTAYBRIDGE SUITES-BALLANTYNE
Address15735 BRIXHAM HILL AVE
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 2/18/2026
Final Score @ Grade
10
General CommentsVerified following for spa filtration system: Permit Restriction: -Flow meter must remain operable. Flow required at 24 gpm to 40 gpm to meet turnover and flow restriction of the number of returns. -New Pump Pentair Intelliflo3 VSF, 1.5 hp. -FlowVis flow meter reading above flow restriction. -(2) Aquastar A10RCFRxxx drain covers 2017. -(1) skimmer with EQ line plugged in skimmer/plastered on wall -(1) Pentair TR60 filter. -(2) returns (2 returns for filtration are on lower part of spa wall, other 6 returns are connected to jet system, per pool contractor) Flow observed at 40 gpm. Unable to locate model “011065” on filtration pump. Verified Pentair Intellifo3 VSF 1.5 HP, SVRS Breather1 being checked monthly Inspection with Michael Brumbles Changed to “A” Open for Business

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
20 4 Premises: caution signs posted at hot water spas No No No Signage added word “the” before blood pressure etc. .2532(15) Provide Caution sign in 1/2" lettering 1/2" in height according to Rule .2532(15). Operator removed word and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No 3' clearance around piping. Floor not sloped to drain. Pool built 2001. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(d) Pump room floor shall be sloped to drain. One bag of dry chemicals on floor in chemical storage. Light out in chemical storage. .2533(b) Provide sufficient lighting in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No New piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in men’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.