Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSTAYBRIDGE SUITES-BALLANTYNE
Address15735 BRIXHAM HILL AVE
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 5/14/2025
Final Score @ Grade
20
General CommentsImmediate suspension issued for water quality. Other permit items to check on return visit include record keeping, SVRS testing, TA, no cyanuric acid in spa. Contact Marie Daley at 704-507-6806 to lift suspension. Spa must remain closed until suspension is lifted by Health Dept

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No G.S. 130A-2(3) Chlorine bleached out test kit. Imminent Hazard to public. Lower to measurable level.
3 6 Water quality: pool water pH No No No pH 6.8 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Total alkalinity not recorded weekly. Record weekly. SVRS on both filtration and feature pumps. Drains are less than 36" apart. Requires monthly testing per mfg. instructions. Record in log book. Cyanuric acid over 200 ppm, should not be in indoor spa. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. Permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No 3' clearance around piping. Floor not sloped to drain. Chemicals in pump room. Pool built 2001. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(d) Pump room floor shall be sloped to drain. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Water over 110 F in restrooms. .2526(i) Water in restrooms shall not exceed 110 F.