Water quality: water clear enough to clearly see bottom of pool and pool drain |
No |
No
|
No |
Water not clear enough to see main drains at time of inspection. .2535(2) Main drains must be clearly visible from the pool deck.
*Immediate Suspension item |
|
4
|
6
|
Water quality: water temperature of heated pool |
No |
No
|
No |
Spa over 104 F at time of inspection. .2535(12) Heated spa temperature greater than 104 F. Maintain spa temperature at 104 F or below.
*Immediate Suspension item |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing weekly alkalinity, unable to locate past month of records and main drains marked checked, but cover was missing at time of inspection.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Operator checked alkalinity and recorded. Will check records at return visit.
*Permit item |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Drain cover missing in bottom of spa. .2537(7) Drain covers shall be in good condition and securely attached.
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7.
.2539(d) All drain covers shall be kept in good condition. Missing, broken, or cracked fittings shall be replaced or reattached before the pool should be used.
*Immediate suspension issued. Submit updated PDSC if updated to pdsc@mecknc.gov and contact Marie Daley at 704-507-6806 when in compliance to lift suspension.* |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No 3' clearance around piping. Floor not sloped to drain. Pool built 2001. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be sloped to drain. |