1
|
6
|
Water quality: water clear enough to clearly see bottom of pool and pool drain |
No |
No
|
No |
Water not clear enough to see main drains at time of inspection. .2535(2) Main drains must be clearly visible from the pool deck.
*Immediate Suspension item |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 8.4 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8.
*Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing weekly alkalinity and pH out of range multiple days.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Operator checked alkalinity and recorded. Will check records at return visit.
*Permit item |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
No spare pump basket for spa at time of inspection (Challenger CHII-NI-1/2FE) .2518(e) Provide a spare basket for pump.
*Permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No 3' clearance around piping. Floor not sloped to drain. Water under jet pump in equipment room. Pool built 2001. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be sloped to drain.
.2533(d) Pump room floor shall be kept dry and free of standing water. |