Inspection Date 7/18/2023
Final Score @ Grade
16
General CommentsIssued permit. No Night Swimming. Pump missing placard, motor observed 3HP (rather than 2 HP). Referring to Code for electrical permit, not found in system for motor change out.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No G.S. 130A-2(3) Chlorine bleached out test kit. Imminent Hazard to public. Lower to measurable level. Operator drained added water and adjusted to 8 ppm.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid missing on records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. No 3’ clearance. Pool built 95 .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Piping missing labels. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.