Water quality: pool water pH |
No |
No
|
No |
Obseved pH to be 6.8 or less. pH must be 7.2-7.8 for safety. PERMIT SUSPENDED SPA CLOSED TO SWIMMING |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed daily and weekly log records not properly kept. Daily and weekly checks must be performed and logged every day the pool/spa is open for use. This includes weekends and holidays if the pool/spa is open for use. The CPO must observed the pool/spa every day it is open for use. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Observed EQ cover missing from skimmer line. Observed pump information on PDSC form to be incorrect. Filtration system appears to be a WFE-8 2HP pump while Jets are a Hayward RS2000. This is not reflected in what has been submitted to the Health Department. Replace the EQ line cover with appropriate cover and submit new corrected PDSC forms to the Health Department for approval. PERMIT SUSPENDED SPA IS CLOSED TO SWIMMING. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Observed fittings missing from returns/jets inside the spa. Replace the fittings. |
|
14
|
4
|
Pool maintenance: spa timer working properly |
No |
No
|
No |
Observed spa timer damaged, unable to test timer. Repair timer and ensure it activates jets for no longer than 15 minutes at a time. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed flow meter stuck. Repair it. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed floor of pump room wet from possible leak. Fix any leaks. Observed chemical in open paper bag stored on the floor. Do not store such items on the floor. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Observed no air gap at the backwash line. |