Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWESLEY VILLAGE APARTMENT HOMES
Address2715 WET STONE WAY
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/30/2021
Final Score @ Grade
22
General CommentsIntent to Suspend issued for record keeping, test kit reagents, return fitting, repair to gate latching mechanism and repair to double door (self-close, self-latch). A return visit will be made in 30 days to verify completion of Intent to Suspend items. If not corrected, permit will be suspended. Chris Baker, maintenance supervisor, present during the inspection. CPO currently expired. Keith Stewart, CPO certified.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No logs kept for September. Maintain record keeping. Daily records for chlorine, pH and main drain checks. Weekly checks for alkalinity and cyanuric acid. Intent to Suspend issued. Some reagents expired in test kit. Replace expired reagents. Intent to Suspend issued.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One return fitting missing on wall near step. Replace fitting. Intent to suspend issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One door into restroom area not self-closing, self-latching. Repair to self-close, self-latch. Intent to Suspend issued. Gate latch loose on far left gate at back entry. Secure gate latching mechanism. Intent to Suspend issued. .2528 fencing- ensure there are no footholds on outside of fencing at 45" or lower. Observed lamp posts at 38" directly outside fence with a 4" rim at top of lamp post that could act as a foothold. Pool built prior to 2010 therefore no permit action. Window limiters could not be verified on windows. Ensure windows open 4" or less on to pool deck.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool furniture <6 ft. to pool edge. Moved during the inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet. Keep dry. Could not locate leak if present. Bags of chemicals storage in pump room. Store in chemical storage room. No room in chemical storage room to store chemicals. Clean out chemical storage room to provide required space for chemical storage. Pump room and chemical storage room unlocked. Keep locked when not in use.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Labeling wearing off on piping in pump room. Clearly identify all piping with color codes or labels.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >113 F. Maintain at 110 F or below. No toilet paper in men's restroom. Provide toilet paper.