Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWESLEY VILLAGE APARTMENT HOMES
Address2715 WET STONE WAY
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/11/2017
Final Score @ Grade
26
General CommentsPermit posted is for last year. Go to Meckpools.charmeck.org to print copy of new permit to post in the pool area. Ensure that all windows that open onto the pool deck are not able to open more than 4". Pool hours are 9:00 AM to 10:00 PM. Ensure that there is at least 10 foot candles of light to all parts of the pool and required deck area.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool floor dirty. Vacuum regularly.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing one of six weirs. Install functional weir.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Missing inlet fitting at steps near grill area. Install directional eyeball fitting.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gaps > 4" in fence. Maintain fence such that no gaps > 4" exist. Fence < 48" in places. Foothold along brick wall. Maintain fence at least 48" high.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck chipping and handrail for steps. Maintain deck in good condition.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter sticking. Remove debris from the flow meter or replace flow meter. Pressure guage for far filter does not appear to be working. Unable to test. Test pressure guage and replace if needed.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in chemical storage room. Provide either cross or forced air ventilation for chemical storage room. Unable to check fan in pump room. Ensure fan is working.