Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWESLEY VILLAGE APARTMENT HOMES
Address2715 WET STONE WAY
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/10/2016
Final Score @ Grade
28
General Comments22 - General Comment: 911 operator breaking up when called. Operator stated they could clearly hear inspector. Assure phone connecting properly to 911. 911 should be clearly audible. Intent to Suspend issued for record keeping and door on to pool deck.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Alkalinity and acid not recorded weekly. Record weekly. Intent to Suspend issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Debris on pool floor and build-up on wall tiles. Keep pool walls and floor clean and in good repair.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers with debris/leaves and build-up on inside of skimmers. Keep baskets free of debris to allow for proper circulation. Clean skimmers. One weir missing from skimmer. Replace weir.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door into restroom with push to exit not operational. Door not self-latching, self-closing. Repair. Intent to Suspend issued. Pool built prior to 2010. - 3" under fence and gate at pato gate at front of pool. Maintain 2" or less. - Light located outside of fence <45" in height. Eliminate footholds. - Windows open on to pool deck >4". Install window stoppers to limit window openings to <4". - Push to Exit and Panic Bars <54" in height. Maintain all gate latches at 54". Note: Back gate still sticking. Gate is operating properly.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck damage at ladder handrail. Repair deck.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Fill line leaking in pump room. Repair leak.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light in pump room burnt out. Fan not operational in chemical storage room. Repair lighting and provide continuous forced ventilation or cross ventilation in chemical storage room. Pump room floor wet due to leak. Keep dry. Pipe from fountain filter backwash across floor. Provide 3 ft clear walking space around all equipment.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Some hose bibs on pool deck without backflow prevention device. Provide backflow prevention device on all hose bibs.