NameTYVOLA CENTRE APARTMENTS
Address625 CAMERON WALK CT
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/21/2023
Final Score @ Grade
14
General CommentsInspection conducted with Jacob Abshire. Intent to suspend issued due to distance between depth markers on deck greater than 25’. Once corrected, call Hope McINTOSH AT 980-229-7549 or re-visit will occur within 30 days. If not corrected, permit will be suspended. Night swimming not currently approved.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmers with accumulated debris. Emptied during inspection.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Observed linear distance between 3’ and 4’ depth markers on right side of pool perimeter distance between at 34’. Coping work completed last year and depth markers are now too far apart. Distance between depth markers cannot exceed 25’. Intent to suspend item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Entry doors from office onto pool deck do not latch shut when closed. Bells added to door as audible alarm. Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Horizontals on gate and fence 44". Pool built 2000. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier..2528(b) Horizontals shall not be located less than 45" in height.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Less than 3’ walking space around equipment in pump room. Water on pump floor. Pool built '00. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.