Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTYVOLA CENTRE APARTMENTS
Address625 CAMERON WALK CT
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/19/2021
Final Score @ Grade
32
General CommentsIntent to Suspend (ITS) for weirs, broken coping, gates self-closing, self-latching, spare pump basket (Pentair Whisperflo XF XFE-12 022010), pool floor. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. "W" ITS status. Inspection with Cody Roberts No signature due to COVID No Night Swimming Pool not heated

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Debris and leaves on pool floor. .2537(14) Keep pool surface and pool floor free of debris. *Permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No 1 of 6 weirs missing at time of inspection .2518(k) Replace missing weirs. *Permit item
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy becketts detached from buoy. Keep in good repair. 2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Rope tangled at time of inspection. Keep accessible. .2530(a) Lifesaving equipment should be conveniently located. Operator replaced with new buoy, untangled rope and attached to new buoy. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates not latching at time of inspection due to system being out from lighting. .2537(b) All gates and doors shall be self-closing, self-latching. Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Horizontals on gate and fence 44". Pool built 2000. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier..2528(b) Horizontals shall not be located less than 45" in height. *Permit item-Gates only
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Coping by 3 FT depth marker broken, cracked and chipped more than 1/2". .2537(3) There shall be no loose coping. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. *Permit item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No No spare pump basket time of inspection. .2518(e) Provide a spare basket for pump. *Permit iitem
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Bag of dry sodium bicarb leaning against liquid chemical vat. Pump room without 3' clear walking space around equipment. Pool built 2000. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Operator moved chemicals and corrected. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Pool built 2000. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in restrooms. Provide soap at sinks. Damage to handicap chair in women's restroom. Keep fixtures in good repair.