NameTYVOLA CENTRE APARTMENTS
Address625 CAMERON WALK CT
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/16/2020
Final Score @ Grade
16
General CommentsITS for weirs, coping, gates and doors self-closing, self-latching or audible alarm and fence height 48" from outside barrier. General Comment: 15) Buoy becketts observed peeling and detached. Lack of severity does not warrant Immediate Suspesnion at this time (still attached), but voids the US Coast Guard Approval. Allowed 30 days for replacement and will verify at ITS return visit. Failure to replace will result in permit action. No signature due to COVID-19. Inspection with Geoff Lee Report to geoff@tyvolacentre-apartments.com

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No 2 of 6 weirs missing at time of inspection .2518(k) Replace missing weirs. Will verify on return visit.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Two rubber stoppers observed missing on ladders. One ladder loose. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence by pump room and fencing by side gate less than 48" in height due to landscaping and mulch. Observed one gate hinge broken, not self-closing, self-latching. One glass door not alarmed or latching at time of inspection. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. .2537(b) All gates and doors shall be self-closing, self-latching. *30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Coping by 3 FT depth markers, on both sides, loose, cracked and chipped more than 1/2". .2537(3) There shall be no loose coping. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. *30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some items stored around piping and equipment in pump room. Pool built '00. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.