Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTYVOLA CENTRE APARTMENTS
Address625 CAMERON WALK CT
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/17/2019
Final Score @ Grade
24
General Comments15 - Grab rope on ring buoy beginning to degrade. Replace ring buoy with USCG approved within 30 day. 22 - Emergency phone not clearly visible from all areas of pool deck. Provide additional signage within 30 days for location of emergency phone in areas not clearly visible to the public. Intent to Suspend issued for missing weir, damaged skimmer lids, gate latching mechanism providing foothold, and door self-closing, self-latching near emergency phone.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some etching on pool floor, benches and steps. Keep flooring in good repair.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Two skimmer lids with damage. Replace where needed. Intent to Suspend issued. One skimmer missing weir. Replace. Intent to Suspend issued. One skimmer with weir stuck. Repair. Skimmer baskets full of leaf debris. Keep clean in order to maintain functional filtration system.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates on to pool deck with magnetic key latch. Latching mechanism below 40" (ADA required height at 42" or less) and protrudes >1/2". Raise latching mechanism to meet rule requirement or eliminate foothold. Intent to Suspend issued. Door nearest to emergency phone not self-latching. Repair to self-latch, self-close. Intent to suspend issued. Door on to pool deck not self-closing with audible alarm. Corrected during inspection. Fence not 48" in height due to landscaping. Pool built in 2000, pre-2010. Repair fencing to maintain 48" height requirement.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some minor damage to coping near skimmer by bench and edge of coping near bench area. Continue to monitor. If worsens to >1/2" or hazard to public, repair as needed.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor not sloped to drain and holding water. Floor shall be sloped to drain and kept dry. Dry chemicals stored on chemical storage room floor. Maintain dry storage up off the floor.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash lines to pit. Provide air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in women's restroom. Sinks in men's restroom not operable. Provide soap and keep sink faucets operable. Damage to handicap chair in women's restroom. Keep fixtures in good repair.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No backflow prevention device on hose bib in pool equipment room. Provide backflow prevention device on all hose bibs.