8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Debris in skimmer baskets.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy rope too long at time of inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator corrected to 50'. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door from gym onto pool deck not latching at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator corrected to self-latch.
Did not observe stoppers in windows onto pool deck from clubhouse, but did not attempt to open.
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.
**Permit item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Brick protruding more than 1/2" by ladder on left side. Gaps in decking greater than 1/2" at stair entrance.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
**Permit item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Kings III emergency phone not working/operable at time of inspection. .2530(f) Emergency phone shall remain operable.
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.
**Immediate Suspension item. Contact Marie Daley at 704-507-6806 when corrected to lift suspension. Pool must remain closed until in compliance and verified by EHS. *Note: Phone must route to 911 and have correct information to call back to phone in case of emergency. |