NameTYVOLA CENTRE APARTMENTS
Address625 CAMERON WALK CT
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/15/2015
Final Score @ Grade
30
General Comments#11 Ladder loose (near grill area) & is raising pavers. ** Resolve. GC #21 Pool wall light with "riser" ring missing caulk (leaving gap). ** Re-caulk where needed. INTENT TO SUSPEND issued for #9, #16 & #17. Note: Water added to pool via the circulation system & a backflow prevention is located near the street. Verify that this backflow device does not serve both the pool & the irrigation system. ** See .2512(b).

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Some daily entries missing in pool records. ** Maintain complete records. If pool is closed, indicate such on record.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some soil/ scum on pool wall tiles. ** Clean. Etching on pool floor. ** Keep plaster in good repair.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Two (of 6) weirs missing. ** Corrected while EHS on-site.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No No diving marker tile cracked & is no longer adhered to pool deck. ** Replace tile & secure. (Intent to Suspend/ ITS)
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate (near grill area) will not self-close. ** Adjust. Clearance up to 8" under fence in 2 areas. Maximum allowed is 4". (ITS)
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pavers raised @ loose ladder creating >1/2" offsets. ** Correct. (ITS)
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Forced air vents in chemical & equipment room operate with light switches. ** Forced air fans should run continuously.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash pipes inserted down into sump. ** Provide complete air gaps.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Hose bib in equipment room does not have a backflow prevention device (& the end of the attached hose is down in the sump). ** Install vacuum breaker on hose bib.