NameTYVOLA CENTRE APARTMENTS
Address625 CAMERON WALK CT
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/4/2015
Final Score @ Grade
34
General CommentsIntent to Suspend issued for light pinch hazard and deck protrusions. Body hook located behind bushes and not accessible. Move to an accessible location by return visit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some etching on pool floor and steps. Keep plaster in good repair.Pool light >1/2" from pool wall. Repair to wall to eliminate pinch hazard. Intent to Suspend issued.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir without skimmer. Replace weir.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Two ladders missing end caps. Replace where needed.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One inlet missing fitting. Replace fitting.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No > 1/2" protrusion of deck pavers at 3 ft and at 3 1/2 ft in multiple locations. Eliminate trip hazard. Intent to Suspend issued.
22 6 Premises: emergency telephone provided No No No Phone number worn off emergency phone. Corrected during inspection. 911 operator was hard to hear. Possible connection issue. Have Kings III out to property to check electrical lines.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Keep operational.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line to pit. Provide air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One sink not operable in women's. Repair sink.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No backflow prevention device on hose bib in pump room. Provide backflow prevention devices on all hose bibs.