Inspection Date 6/7/2022
Final Score @ Grade
22
General CommentsEnsure that windows which open onto the pool deck do not open more that 4 inches. Pool has passed inspection and has been issued the permit decal. Paper permit will be available for print out at the Health Department Pool site. Print the permit and keep the pool permit and decal visible to the public.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 1 weirs missing out of 3 total. Pool still has more than 50% weirs. No Permit Action taken.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Observed line opening fitting plug to be broken off presenting a sharp point that is a hazard. New plug was installed. -CDI
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope to be 28 feet long. 38ft. Length is required. -CDI new correct rope was provided.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed door to office to have sensor which allowed door to unlatch automatically, but not have audible alarm. Door was corrected to self-close and self-latch. Maintain correction. -CDI.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed signs not to have lettering at the correct height, 1/2” letters. New corrected signs were provided. -CDI