3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed pH below 7.2.
Immediate suspension issued.
.2535(1) Maintain pH at 7.2 to 7.8. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed records not complete for TA and CYA, completed during inspection. TA has been recorded improperly in past at 10. Ensure proper amount is posted per test kit requirements. Cyanuric acid is over 100 ppm.
Intent to suspend.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed skimmers full of leaves.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed cap sunk below deck on left side. Maintain cap flush with deck.
Observed 1"x12" section of deck cut out at edge of pool on back right side of pool.
Intent to suspend
.2537(2) Decks shall be kept in good repair. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Observed life guard warning sign, sign present has 3" letters.
Intent to suspend
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed no cross ventilation on chemical storage closet.
.2533(3) Provide continuous forced ventilation or cross ventilation in pump room. |