Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBLAKENEY RACQUET CLUB
Address10607 REA RD
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/30/2023
Final Score @ Grade
18
General Comments30 Day Intent to Suspend (ITS) issued for flow meter. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Unable to verify permit restrictions were met for slide/feature pump due to slide being off and uninstalled at time of visit. Main drain screw cover loose for slide. The slide permit restrictions and Derain covers will be verified at return visit. Failure to meet compliance will warrant permit suspension. Send lighting verification of outside lights to Marie Daley at 704-507-6806 for night swimming verification.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Reagents expired. Ensure chemical reagents are within date. Operator discarded expired reagents. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed gate nearest at entry not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. Gate was adjusted to be self-latching. Corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck by slide chipped, greater than 1/2”, but mat covering offsets and slide will be installed. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Mat covering will be corrective action. Continue to monitor this area.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed flow meter for filtration system non-operational. .2518(g) Keep flow meter operational. *Permit item
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hose bib by restrooms observed without backflow prevention. Provide backflow prevention/anti siphon device.