Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBLAKENEY RACQUET CLUB
Address10607 REA RD
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/11/2018
Final Score @ Grade
12
General CommentsObserved 911 phone to work functionally, but to have static in the line. Check phone periodically and ensure proper functioning of 911 phone. Observed the main drains to have Aquastar 18MF101 covers on the walls. These covers may be intended for floor use only and may not be suitable for wall mounted main drains. This may require immediate correction and the pool may have to be closed to swimming until the correction is made an amended PDSC forms are submitted to The Health Department. C. Elmore will follow-up with the pool operator to confirm what actions must be taken after double checking the main drain cover information with supervision. The I.T.S. will expire 5/11/18. A follow-up visit will be made no later than 5/14/18 to ensure the I.T.S. corrections are made. If they are not complete, the pool will be closed to swimming until they are complete. If the pool is to be open for night swimming an evaluation visit after sundown will have to be scheduled with C. Elmore to ensure sufficient lighting. Without this evaluation and sufficient lighting in the pool and on the deck, swimming will not be allowed after sunset and before sunrise.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed 9 skimmers out of 12 missing their weirs. I.T.S. Issued. Replace the weirs and keep them in the skimmers.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Observed 1 return missing the screw-on fitting. Replace the fitting.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed holes for posts present in the deck near ladder and stair rails at several points on the deck. These holes must be fitted with covers or plugs that fill the hole making it even with the deck to no more than 1/2 inch variance from the level deck surface. I.T.S. Issued.