Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCARRINGTON ROSECLIFF CLUB
Address5701 CARY RIDGE DR
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/7/2025
Final Score @ Grade
54
General CommentsWayne Lowery present during the inspection. Intent to Suspend issued for: .2525 - Heaters are accessible to public. Heaters shall be inaccessible to the public. .2535 - maintain daily record keeping for chlorine, pH, main drain, and temperature checks. .2518 - replace damaged pressure gauge. .2513 - install sight glass and air gap on backwash line. .2528 - repair opening between post and gate (main entry) so 1/2" or less; install limiters on windows from club building at 4" or less. .2524/.2537 - no night swimming approval. Provide documentation showing sufficient lighting for night swimming approval. .2537 - repair deck and coping at step entry. Note: Lane covers are used. Pool is kept open to the residents of the community when not in use by swim team. Lane covers cannot be in place at ANY time the pool is open to the public. Contrasting color bands will require repair prior to 2026 operating permit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No daily record keeping maintained. Ensure daily record keeping for chlorine, pH, temperature and main drain checks. Intent to Suspend issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Debris on pool floor. Tent sides are not secured and allow for debris to blow underneath. Vacuum regularly to keep clean. Chipping paint on fiberglass. Missing lane lines. Operator stated repair will occur prior to 2026 operating permit. No chipping paint severe enough to present a hazard at time of inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer basket with minor damage at deep end. Replace skimmer basket.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Step handrail loose. Deep end handrails on ladder loose. Tighten. Keep handrails in good repair.
13 4 Pool maintenance: contrasting band on steps and benches No No No Chipping paint on contrasting color band. Provide 2" thick contrasting band to edge of step prior to 2026 operating permit.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy throw rope fraying. Replaced with 50 ft. rope during the inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Distance between post and gate at main entry gate >1/2". Maintain at 1/2" or less within 18" of push bar. Windows from back club building into pool with limiters sticking. Limiters shall be repaired to limit windows at 4" or less. Building was added with renovation. One picket with >4" near parking lot. Ensure 4" or less between pickets. Fence around garden on back side of equipment room building provides horizontal with less than 45" - pool access point. Eliminate footholds. Pool built 1990.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Damage to pool deck/coping at main step entry into the pool. Repair damaged/cracked coping. Damage to pool deck with chipping pieces of concrete at main step entry to the pool. Replace damaged decking/coping at step entry. Intent to Suspend issued. Some other areas with damaged deck. Offsets not >1/2". Monitor and repair as needed.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Pool not approved for night swimming. Night swimming approval drawn during site visit. Need documentation of sufficient lighting for night swimming. No public is permitted in the swimming pool without night swimming approval. Pool has swim team that practices after hours. Intent to Suspend issued.
22 6 Premises: emergency telephone provided No No No Emergency phone signage with address spelled incorrectly. Corrected to "Cary" during the inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pressure gauge on one filter missing glass. Replace pressure gauge. Intent to Suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light in pump room not operable. Provide lighting.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap or sight glass on backwash line to pit. Provide air gap/sight glass for backwash. Intent to Suspend issued.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >115. Maintain at 110 F or below. Left sink in women's restroom leaking and not draining. Repair sink. Shower fixtures in women's restroom with build-up. Keep clean. Some stalls without toilet paper. Ensure all toilets have toilet paper. One restroom stall locked. Keep all restrooms accessible.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Damaged flooring in women's restroom. Keep in good repair so easily cleanable.