15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed 1 body hook detached from pole. Observed 2nd body hook attached to 9 foot pole. CDI- new poles and body hooks provided.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope detached from one ring buoy. CDI- rope was reattached. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed 2 doors from clubhouse to pool deck that are audibly alarmed but not self-closing. Observed alarms disabled. The alarms were activated, ensure door chimes remain turned on at all times. Intent to suspend issued for doors not self closing. Correct within 30 days by 8/21/2021. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed 2" diameter holes in pool deck. CDI- flagpoles installed into holes. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Observed non-operational flow meter. |