Water quality: disinfectant residual provided by |
No |
No
|
No |
Bromine 0 ppm at time of inspection. .2535(5) Maintain bromine at least 2.0 ppm.
**Immediate Suspension (IS) item. Contact Marie Daley at 704-507-6806 when corrected to lift suspension. Pool must remain closed until IS lifted by EHS. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH over 8.4 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8.
**Immediate Suspension (IS) item. Contact Marie Daley at 704-507-6806 when corrected to lift suspension. Pool must remain closed until IS lifted by EHS. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records since March. Records have days missing with "OFF", indicating pool not being checked and multiple days with water quality out of complaince (pH 8+) and no corrective actions or maintenance.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
**Permit item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Both weirs missing at time of inspection. .2518(k) Replace missing weirs.
**Permit item |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
"0 FT" Depth markers removed from pool wall and deck at sunshelf, leaving "3 IN". .2523(c) Depth markers shall include the word "feet" or symbol "ft". .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool.
**Permit item (Options add "0 FT" in front of 3 IN or replace with "1/4 FT") on deck and pool wall |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Beckett detacthed on ring buoy of one buoy at time of inspection, voiding USCG approval. .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
**Immediate Suspension (IS) item. Contact Marie Daley at 704-507-6806 when corrected to lift suspension. Pool must remain closed until IS lifted by EHS. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Ventilation not working in chemical room at time of inspection. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |