2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine 0.2 ppm at time of inspection. Maintain chlorine at least 1.0 ppm.
**Immediate suspension item. Contact Marie Daley at 704-507-6806 when addressed to lift suspension. Pool must remained closed until visit is made to verify compliance and reopen. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Sun shelf only read "3 IN". Depth markers shall include the word "feet" or symbol "ft". (On wall and deck).
*30 day ITS item |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy wrong length (16'). Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator corrected to 21'. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Chlorinator not working properly, leak coming from piping at time of inspection. Keep in good repair and working according to manufacturer's instruction. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Maintain 3 ft clear walking space around piping. Pool built prior 2010. |