Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHYATT HOUSE
Address435 E TRADE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/18/2024
Final Score @ Grade
16
General Comments22- 911 has 435 Trade St. on file. Pool address is 435 E. Trade St. Correct address so that 911 has the correct address within 1 week or permit will be suspended. Intent to Suspend issued for: .2537 - affix light to wall to eliminate offset. .2537 - provide night lighting documentation to show sufficient lighting present for night swimming approval. Dontae Johnson present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Two days missing main drain checks in March and two days in February. Maintain daily record keeping for main drains.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Pool light not secure to wall with gap and fitting loose. Repair light to wall. Intent to Suspend issued.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Pool is approved for night swimming on permit. Provide night lighting documentation to renew night swimming approval. Pool hours until 10:00 pm. Intent to Suspend issued.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One sink not operable in left restroom. Repair sink. Keep all sinks operable.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No backflow prevention device on hose bib on shower. Provide backflow prevention device.