5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Pool heater on. Temperature not recorded daily. Maintain daily record keeping for temperature of pool. Intent to Suspend issued.
DPD-2 Reagent expired. Electronic test kit not operating. New test kit ordered to be delivered on 10/28. Replace expired reagent. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some etching on pool floor. Monitor and repair as needed. Plaster is new. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer weir in upside down. Install weir to meet NSF approval. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Step handrail slightly loose. Tighten. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
New filter installed - Jacuzzi JSF26 rated for 70 gpm. Design flow of pump at 70 gpm. New filter only just approved with design flow of pump.
No NSF listing for filter. Could not find a spec sheet for filter showing that it is NSF approved. Not listed on NSF website. Provide spec sheet for filter showing NSF approval or replace with NSF approved filter. Intent to Suspend issued.
No air relief valve on filter. Install per rule requirement. Filters shall have air relief valves located at top of filter. Intent to Suspend issued
Leak at top of filter. Filter sounds to be sucking air. Repair leak. Intent to Suspend issued.
Flow meter stuck. Repair so operable. Intent to Suspend issued. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
New plumbing run in pump room with replacement of heater and filter. No air gap at backwash line to pit. Did not view sight glass on filter. Provide air gap into backwash pit to ensure no cross connections and that backwash water can be viewed. Intent to Suspend issued. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
One sink in women's restroom not operable. Replace batter so that sinks remain operable. |