7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Etching and chipping plaster on pool floor. Facility is currently in process of getting pool re-plastered. New plaster, tile and wall tile to be replaced. Ensure pool plaster with light reflectance >50% and that when step tile replaced, ensure no greater than 1" from step edge and pool wall. Tile shall be at least 2x2 tile. Keep flooring in good repair as not to present a hazard to the public.
Some tiling missing from pool waterline tile. Replace where needed. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some debris under skimmer basket on skimmer furthest from pump room. Ensure skimmers are kept clean. Clean under baskets.
Loose collar around lip of skimmer closest to pump room. Secure collar to meet NSF approval.
Weir installed on lower part of skimmer lip but upside down with Styrofoam facing up. Install skimmer weirs per mfg. instructions. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Damaged paver on pool deck. Offset not greater than 1/2"; however, monitor and repair/replace if worsens. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator. Original construction. If ever repaired/replaced, ensure flow meter installed on chlorinator inlet line. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Middle sink in women's restroom not operable. Battery appears dead. Keep sinks operable.
One soap dispenser broken in men's restroom. Repair/replace soap dispenser. |