Inspection Date 3/9/2020
Final Score @ Grade
20
General Comments22 - General Comment - Emergency phone number calls back the front desk to an automated answering service. 911 must be capable of calling back line to reach caller/or front desk if manned 24 hours per day. Given 30 days to repair. Permit will be suspended if not corrected within 30 day timeframe. Intent to Suspend issued for flow meter. Per operator, like for like change on pump. Permit had been pulled and passed inspection. E3656761.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some damage to pool floor. Does not appear to present hazard. Some etching on plaster. Keep pool floor in good repair.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Weirs stuck in place/backwards. Corrected to function properly during inspection.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Handrail at steps loose. Keep in good repair. Tighten so as not to present a hazard.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope at 26 ft. Corrected to 24 ft. (required) during inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Keep operational. Intent to Suspend issued.