| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing temperature. Pool has changed company that services pool. Provide updated certification for CPO.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator.
* Permit item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Weir missing at time of inspection. .2518(k) Replace missing weirs.
*permit item |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder at left end of pool broken with step hanging off bottom. Not secure. Unable to be used. Severity warrants permit action.
.2521(a) Steps or ladders shall be provided every 75 ft along the shallow area perimeter.
.2521 Install ladders per manufacturer instructions.
*Permit item |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Back door not latching or alarmed. Door onto pool deck not latching or alarmed at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*Permit item |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs and bench within 5' of pool at time of inspection.
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times.
Operator moved and corrected.
Decking flooded with water and buildup in some areas, especially back wall due to HVAC in disrepair. Not draining, clean or slip resistant.
.2522(f) Deck shall be sloped to drain.
.2522(g) Decks and walkways shall be slip-resistant.
*Permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Equipment room unlocked. Ventilation not working in chemical storage. Dry bag of chemicals on floor in pump room. Chemicals in pump room.
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. |
|