Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLA FITNESS AND PRO RESULTS
Address12325 COPPER WAY
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/13/2025
Final Score @ Grade
24
General Comments30 Day Intent to Suspend (ITS) for records, doors onto pool deck and weirs. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. “W” status Inspection with Maddy Gast Note: Skimmer equalizer covers expire in January 2026. Replace or plug per state recommendations and submit updated PDSC form prior to expiration to avoid permit action.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing temperature and cyanuric acid in pool (indoor) should not be high/present. Heater off at time of inspection. Note in records if temperature is not recorded. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Multiple weirs missing at time of inspection. .2518(k) Replace missing weirs. *permit item
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope tangled and not accessible. Operator untangled and corrected during the inspection. .2530 Ensure ring buoy rope is kept accessible.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back door not latching or alarmed. Women’s locker room door not latching or alarmed at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. *Permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs and bench within 5' of pool at time of inspection. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Operator moved and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Equipment room unlocked. Ventilation not working in chemical storage. Dry bag of chemicals on floor in pump room. Chemicals in pump room. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.