| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 6.8. Operator added chemicals but did not increase pH. Immediate Suspension issued. Permit suspended. Pool pH shall be maintained at 7.2 to 7.8. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Ensure weekly record keeping for Cyanuric Acid. Pool has switched to tablet feeder. Automated feeder not operable. No CYA recorded.
Some days missing main drain checks. Ensure daily record keeping for main drain checks. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Severe etching and discoloration of pool floor. Damage to plaster can cause issues with pool chemistry. Pool does not meet light reflectance value of greater than 50% in some areas. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
All skimmers missing weirs. Replace skimmer weirs. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy rope tangled and not accessible. Corrected during the inspection. Ensure ring buoy rope is kept accessible. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Both doors to locker rooms not self-closing, self-latching. Repair doors to self-close, self-latch.
Front entry door propped open. Ensure kept closed to self-close, self-latch. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs at 3 1/2 ft. to pool edge. Maintain 5 ft. clearance around the pool.
Some algae build-up on floor at 3 1/2 ft. coping. Eliminate algae. Standing water at deck at entrance from men's locker room. Deck shall be sloped to drain with no standing water. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Lights could not be verified in the pool. Lights shall be operable for night swimming approval. Ensure lights operable or provide lighting documentation showing pool floor clearly visible at night with overhead lighting. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Chlorinator for stick feeder not operable. Filled with chlorine. Ensure operable flow meter installed per NSF specifications. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Right side chemical storage room with light burnt out. Provide lighting in chemical storage room.
Equipment room door left unlocked. Ensure locked when not in use. |