Water quality: water clear enough to clearly see bottom of pool and pool drain |
No |
No
|
No |
Water quality observed murky. Unable to clearly see main drains. .2535(2) Main drains must be clearly visible from the pool deck.
**Immediate suspension item.*** |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records for previous days and end of last month. Entries recorded on days that do not exist (31st day of months with 30 days). Same readings for TA every day. Records should be accurate and kept daily.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmers observed with buildup and debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
*permit item |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs and bench within 5' of pool at time of inspection.
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times.
*Permit item
Deck chipping around coping, offsets greater than 1/2ā.
.2537(2) Decks shall be kept in good repair.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*Permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Equipment room unlocked. Ventilation not working in chemical storage.
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |