Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLA FITNESS AND PRO RESULTS
Address12325 COPPER WAY
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/16/2021
Final Score @ Grade
22
General Comments6) PDSC has incorrect Model number for pump. Intelliflo VS + SVRS model 011017. No suction hazard present. Same pump curve. Update PDSC form at submit within 7 days to avoid permit action. Immediate Suspension for water quality. Changed to "E" Immediate Suspension status. Pool must remain closed until suspension is lifted by Health Dept. Contact Marie Daley at 704-507-6806 when in compliance to lift Other permit items flow meter, chlorinator and PDSC form (pump model) No signature due to COVID. Inspection with Josh Evans Report to robd@fitnessintl.com and danny@aquatechpm.com

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 6.8 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Immediate Suspension item. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Pool MUST REMAIN CLOSED until suspension is lifted by Health Dept.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Items (chairs, signs) within 5' of pool. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Manager moved items and corrected.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Automatic feeder not functioning properly at time of inspection. Pool operator onsite, fixing. Will verify feeders on return visit. .2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not working at time of inspection. .2518(g) Keep flow meter operational. *permit item. Will verify on return visit.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Ventilation not working in chemical storage. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Drain grate at backwash observed broken into the pit. Keep in good repair. .2513(b) Filter backwash shall be discharged through an air gap.