General CommentsITS for trip hazards and doors self-closing, self-latching or audible alarm and will verify daily activities of gym to ensure safety needs are being met in absence of pool management company. Floor entry into locker room is not slip-resistant, but not part of pool deck. Advised addressing this safety concern.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 6 Water quality: water clear enough to clearly see bottom of pool and pool drain No No No Skimmer equalizer covers covered with hair and debris. .2535(2) Main drains must be clearly visible from the pool deck. Staff was uncomfortable with clearing drain covers. Pool operator from pool management company was called and corrected by removing debris. Recommended training gym staff to address pool maintenance linked directly to pool safety.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Weir missing at time of inspection. .2518(k) Replace missing weirs. Pool operator came to establishment and replaced. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door propped open from men's locker room for dehumidifier to stay plugged in. Not latching. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Door must stay closed when not in use, and meet compliance at all times.. *30 Day Intent to Suspend (ITS). Contact Marie Daley at 704-507-6806 when item is addressed to lift ITS.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Lane dividers and equipment stored around pool during class. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. *ITS item. Remove items not in use to meet compliance at all times.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pool pump room unlocked and open at time of visit. Chemicals in equipment room. No ventilation in chemical storage at time of visit. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Toilet paper missing in women's restroom stall. .2526(l) Provide toilet paper and dispensers in restrooms. Hot water over 110 degrees F in restroom. .2526(i) Water in restrooms shall not exceed 110 F.