| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 6.8. Overcorrected to 8.2. Maintain pool pH at 7.2 to 7.8. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No test kit. Missing reagents. Provide test kit. Must have test kit prior to reopening the pool. Ensure reagents provided for chlorine and pH. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Staining on top steps into pool. Pool plaster does not meet LRV >50%. Plaster is dark. Clean steps so that floor reflects 50% light.
.2514(c) Pool finish shall be white or light colored. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Two of (7) skimmers missing weirs. Replace weirs.
One skimmer basket damaged. Not broken. Replace damaged basket. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Step handrail loose at steps closest to gate. Tighten handrail. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Rust on Paddock main drains. Eliminate rust or replace. Fixtures shall be in good repair. Some screws missing from drains. Replace screws where needed so secure. Drains have no suction and are just a fitting. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy rope tangled. Corrected during the inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
One gate not closing and the other not latching. Both gates shall self-close, self-latch.
New gate latch on gate closest to pump room. Move to 54" from ground to top of gate latch. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept in good repair. Observed slip resistant coating on deck starting to degrade. Deck is concrete under coating. Monitor slip resistant coating, if degradation worsens a new coating may need to be applied. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Warning signage missing from pool deck. Provide "Warning No Lifeguard on Duty" in 4" lettering, visible upon entry to the pool. Signage had blown down in the wind. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone does not transfer address to 911. No address is transferred. Phone call back not working. Phone shall transfer correct address and phone number to 911. Phone number, when dialed, shall ring back or answer automatically at emergency phone. Immediate Suspension issued. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Small leak at filter lid. Tighten lid to eliminate leak. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms >113 F. Maintain at 110 F or below. |